MODEL FEATURES
 |
Counterfeit Note Detection -- Features the latest counterfeit note detection technology including ultraviolet,
magnetic, infrared and fluorescence detection.
|
 |
Continuous Feed Hopper -- Automatic continuous feeding with a capacity of 1,000 bills. Includes special separator paddles to handle multiple batches at the same time.
|
 |
Multiple Pockets -- Seven sorting pockets, each with a 300 bill capacity. For versatility, multiple pockets can be used for the same denomination.
|
 |
Entry of Non-Currency Items -- Supports the entry and tracking of non-currency items such as coupons, gift certificates, checks, etc.
|
 |
Convenient Offsort Pocket -- Rejected bills are routed immediately to the offsort pocket for individual review and handling.
|
 |
Double Count -- As currency passes through the transport, each note is counted twice, ensuring count accuracy and verification.
|
 |
Adjustable Strap Stops -- Separate strap stop limits can be established for each denomination.
|
 |
User-Defined Operating Modes -- Allows up to 8 pre-set "configurations" to speed transition when shifting between different operations.
|
 |
System Control -- The entire system is operated via a touch-screen monitor or you can use the tactile keypad to enter numbers and amounts. The JetTouch™ operating software is menu driven with operator prompts and large, easy-to-read menu screens. Includes supervisor and operator password controls.
|
OPTIONS AND ACCESSORIES
 |
Bar Code Ready -- An external bar code
gun option allows bar-coded information from coupons
and tickets to be easily input
into data screens.
|
SPECIFICATIONS*
Speed -- 1,000 documents per minute.
Feed Hopper Capacity -- Up to 1,000 bills, with automatic continuous feeding.
Offsort Pocket Capacity -- 300 circulated bills.
Size -- 60-70" H** x 55" W x 30" D
**includes operator-adjustable height control.
Weight -- Approximately 585 lbs.
Power -- Voltage operating ranges are either 105-130v or 198-253v. Frequency is 60/50Hz. Customer must provide an electrical supply properly grounded and protected by a circuit breaker in accordance with applicable electrical code. This equipment must be plugged into a properly grounded outlet. To obtain the best results, Cummins recommends using this equipment in conjunction with a dedicated AC power line.
Power consumption (full load amps) at nominal voltage: 8.0 Amps (120v); 4.0 Amps (220v). Power disruptions that result in input voltage other than the power requirements listed can lead to improper operation of this device or result in failure/damage to electrical components. (Power disruptions are not covered under machine warranty or preventative maintenance agreement.)
Power conditioning/stabilizing is included.